libcamera: pipeline: vimc: enforce stream configuration
The format requested by configureStreams() should exactly match what is programmed on the video device. If they do not match the call should fail as the application in that case will not know what configuration was actually programmed. Signed-off-by: Niklas Söderlund <niklas.soderlund@ragnatech.se> Reviewed-by: Laurent Pinchart <laurent.pinchart@ideasonboard.com>
This commit is contained in:
@@ -83,6 +83,7 @@ int PipelineHandlerVimc::configureStreams(Camera *camera,
|
||||
std::map<Stream *, StreamConfiguration> &config)
|
||||
{
|
||||
StreamConfiguration *cfg = &config[&stream_];
|
||||
int ret;
|
||||
|
||||
LOG(VIMC, Debug) << "Configure the camera for resolution "
|
||||
<< cfg->width << "x" << cfg->height;
|
||||
@@ -92,7 +93,16 @@ int PipelineHandlerVimc::configureStreams(Camera *camera,
|
||||
format.height = cfg->height;
|
||||
format.fourcc = cfg->pixelFormat;
|
||||
|
||||
return video_->setFormat(&format);
|
||||
ret = video_->setFormat(&format);
|
||||
if (ret)
|
||||
return ret;
|
||||
|
||||
if (format.width != cfg->width ||
|
||||
format.height != cfg->height ||
|
||||
format.fourcc != cfg->pixelFormat)
|
||||
return -EINVAL;
|
||||
|
||||
return 0;
|
||||
}
|
||||
|
||||
int PipelineHandlerVimc::allocateBuffers(Camera *camera, Stream *stream)
|
||||
|
||||